profile - دانشکده فنی
دانشکده فنی و مهندسی
پردیس دانشگاه رازی
Bijan Abbasi KHazaei
Associate Professor / Engineering / Materials Engineering and Metallurgy
Master Theses
-
Investigation of the Directed Growth of Silver -Doped ZnO Nanorods within Tio2 Nanotubes for Enhanced Osseointegration and Antibacterial Performance of Dental Implants.
Mohsen Veisee 2026AbstractTitanium dental implants are among the most widely used options for replacing missing teeth owing to their favorable biocompatibility, desirable mechanical properties, and adequate corrosion resistance. Nevertheless, the long-term success of dental implants depends not only on the bulk properties of the material but also on the complex interactions among the implant surface, surrounding bone tissue, and the microbial environment, which play a decisive role in the establishment and long-term stability of osseointegration. Accordingly, the development of engineered surfaces capable of simultaneously providing favorable biological and functional properties has emerged as an important research direction in the field of titanium-based dental implants.In the present study, the spatial architecture of nanostructures was considered the central design parameter. The objective was to design and investigate a hybrid architecture comprising TiO? nanotube arrays and ZnO nanorods, with the aim of promoting ZnO nucleation and growth from within the TiO? nanotube channels and directing the nanorods along the longitudinal axes of the nanotubes, to the extent possible. To this end, titanium sheets were cut, polished, and cleaned before being converted into TiO? nanotube arrays by electrochemical anodization in an acidic electrolyte containing hydrofluoric acid (HF) and acetic acid under a constant applied potential at room temperature. Subsequent heat treatment was performed to promote the formation and stabilization of the anatase phase of titanium dioxide.In the next stage, vacuum-assisted seed loading was employed to increase the likelihood of precursor solution penetration into the internal spaces of the nanotubes. For this purpose, a custom-designed and fabricated vacuum chamber was used. A solution containing a zinc precursor was introduced into the nanotubular structure under controlled conditions, and the seed-loading procedure was repeated over multiple cycles. Subsequently, ZnO nanorods were grown using a hydrothermal method, with particular attention given to the effects of growth conditions on nanostructure formation and morphological evolution.Structural and morphological characterization of the samples was performed using field-emission scanning electron microscopy (FESEM), energy-dispersive X-ray spectroscopy (EDX), and X-ray diffraction (XRD). The results indicated the formation of a hierarchical TiO?/ZnO structure, with ZnO nanorods observed both within and on the surface of the TiO? nanotube arrays. Furthermore, the findings revealed that hydrothermal growth parameters and the seed-loading method directly influenced nanorod morphology, density, and dimensions. Phase analysis also confirmed the formation of the expected crystalline structure.The findings of this study provide a practical basis for controlling the hierarchical architecture of ZnO nanostructures on titanium surfaces. This approach may serve as a foundation for further investigations into osseointegration, biocompatibility, and antibacterial performance, with the ultimate aim of developing surface-engineered titanium dental implants.Keywords: TiO? nanotubes; ZnO nanorods; hybrid architecture; vacuum-assisted seed loading; hydrothermal growth; surface engineering; osseointegration.
-
Investigation of isothermal oxidation kinetics of Ni2Al3 aluminide coating on nanocrystalline nickel
MAHA HAMZAH MOHAMMED 2026The service life of coated components at high temperatures depends on the growth rate and activation energy of the oxide scales formate on their surfaces. While the growth activation energies for, , and cales on NiAl aluminide have been established in previous studies, no data regarding these values for diffusion coatings were found in available scientific literature. The present study aimed to address this gap. To this end, a layer with thickness about 15 was applied on nanocrystalline nickel samples by high activity aluminizing at 475°C. The aluminized samples were then subjected to isothermal oxidation in temperature range of 750°-1050°C at ambient air(oxygen partial pressure of 0.21 atm). Mass changes were recorded at various oxidation durations. The oxide phases were identified using X-ray diffraction. For each temperature, the mass gains and square of mass gains were plotted versus oxidation times. The parabolic rate constants() for the oxide phases were determined by fitting a best straight line to the experimental data using the least-squares method. Finally, the activation energies for the growth of, , and cales were estimated by fitting a line to plot of log against the reciprocal of the oxidation temperature. Based on the obtained results, the amount of oxidized material at 950°C and 1000°C for durations under 25 h was higher than that at 1050°C; conversely, for durations exceeding 25 h, the mass gain at 1000°C was lower than that 950°C. The oxide scale consisted of a single ?-Al?O? phase at 750°C and a single ?-Al?O? phase at 1050°C. At 800°C and 850°C, the ?-Al?O? phase formed initially, followed by the formation of a ?-Al?O? scale. At 950°C and 1000°C, the ?-Al?O? phase formed first and subsequently transformed into ?-Al?O?. Phase transformation at the first two temperatures resulted in increases of 135% and 109% in whereas at the subsequent two temperatures, it caused decreases of 97% and 91%. At 900°C, sequential phase transformations, ??? and ??? and three-stage growth kinetics were observed. The activation energies for the growth of ?, ?, and ? oxide scales on the Ni?Al? aluminide coating were 251, 197, and 403 kJ/mol, respectively. The times corresponding to changes in decreased exponentially with increasing oxidation temperature.
-
Structural Integrity Assessment and Creep Damage Analysis of the Hydrodesulfurization Reactor at Kermanshah Oil Refinery
Kimia Ahmadi Fard 2026 -
بررسي فني و اقتصادي اثر جايگزيني نيوبيم به جاي واناديم در فولادهاي ميكرو آلياژي
Arsalan Safari 2025 -
اثر زاويه بين مهاربند و عضو زانويي بر روي عملكرد لرزه اي قاب هاي KBF
Toraj Rajabi 2025Humans use lateral bracing systems in structures to deal with the lateral force that is applied to structures through earthquakes. In metal structures, braces are used to deal with this force, which behave in tension and compression. Brace systems are classified into different types, such as divergent and convergent brace frames and knee element braces. Convergent brace systems are more rigid than reduced section frames and bending frames, but less ductile. In order to increase the ductility of frames, the divergent brace system was invented by Mr. Popov in 1987. In this system, a member that was located as a connecting beam along the main beam element of the frame was responsible for energy dissipation. After the earthquake, if the beam element was continuous, the entire element would have to be replaced. However, if the connecting beam was guided and flanged to the main beam, it would be repairable and replaceable. In this case, the roof of the floor would have to be destroyed. After this, researchers searched for a system through research and laboratory studies. In 1986, a system called the Knee Brace Frame (KBF) was developed by Mr. Ochoa, which eliminated the shortcomings of previous systems. This system has reduced the cross-section and the bending frame has more stiffness and energy dissipation compared to divergent systems. In this study, the hysteresis curve of the knee brace frame (KBF) was first extracted through finite element software (ABACUS) and compared with the experimental model for verification. Then, by doubling the column length and considering it for the beam length, this rectangular sample was examined and analyzed in three models in ABACUS. In the KBF1 model, the beam length is 5.6 meters and the column height is 2.8 meters. The knee brace length is 0.55 meters. The diagonal brace X is passed through the beam and column X at the connection node, and the diagonal brace is perpendicular to the knee brace, but the knee brace length is not divided into two equal parts. In the KBF model, the beam length 5.6 meters and the column height is 2.85 meters, the length of the knee brace is 0.55 meters. And the diagonal brace is again perpendicular to the knee brace, but the X of the brace does not pass through the X of the beam and column at the connection node and divides the knee brace into two equal parts. Continuing in the KBF3 model, where the beam length is 5.6 meters and the column height is 2.85 meters, the length of the knee brace is 0.55 meters, the X of the diagonal brace passes through the X of the beam and column at the connection node and the diagonal brace is not perpendicular to the knee element, but the length of the knee brace is divided into two equal parts. Continuing in the form of a square model, which considers the height of the beam and column as 2.8 meters and the length of the knee brace as 0.22 meters, and the X of the diagonal brace passes through the X of the beam and column connection node and the diagonal brace is perpendicular to the knee element and divides the length of the knee element into two equal parts, but makes the length of the knee element much shorter, as much as twice the length. The knee element length in KBF1 mode is considered to be 22 cm, which means that the square model shows better stiffness, energy dissipation, and lateral load-bearing capacity than the other models. In this study, the behavior of steel materials and welds is controlled by failure criteria in different parts of the connection and the failure mechanism.
-
Experimental Study behavior of RC beam-column joint using light weight concrete
Omid Rezai 2025 -
Investigating the behavior of a bending frame with a knee brace with joint connection
Mahdi Rezanezhad 2024Humans use lateral restraint systems in structures to deal with the lateral force that enters the structures through earthquakes, and braces are used in metal structures to deal with this force, which behave in a tensile and compressive manner. Braces are classified in different types, such as divergent and convergent bracing frames and knee element bracing systems. Convergent bracing systems have a reduced cross-section compared to frames and the bending frame is more rigid but less malleable, in order to increase malleability. Frames In 1987, the diverging brace system was invented by Mr. Popov. In this system, the member that was located as a connecting beam along the length of the main beam element of the frame was responsible for energy consumption. After the earthquake, if the beam element was continuous, the entire element should be replaced and replaced. If the connecting beam was guided and installed in the main beam with a flange connection, it could be repaired and replaced, otherwise the roof of the floor would have to be destroyed. In 1986, a system by Mr. Ochoa called the knee brace frame(KBF)which fixed the shortcomings of the previous systems. Compared to the divergent and segmental systems, this system has reduced stiffness and more energy consumption of the bending frame. In this study, first, through the finite element software (Abaqus), the hysteresis curve of the bending frame was calculated. With the knee brace, we extracted and compared it with a laboratory model for validation. In the following, we checked the same bending frame by removing the knee element, and then by increasing the length of the knee element and changing the knee connection from bending to joint, which in the first case, considering The bending frame means the connection of the beam to the welded support column and the support bracket (welded) and the increase in the length of the knee element, the stiffness and the energy consumption and the lateral load are increased. In the following, all these models are changed from the connection of the beam to the support column in the previous state to a joint (welded joint). We have changed and considered the bracing to be of the welded type, which reduces the hardness, energy consumption, and side load a little, which in the following is in a similar model, such as the verification sample of the connection of the beam to the hinged column (welded) and considering the brace to be of the hinged type (pin) Considering that the hardness and energy consumption have decreased, but the resistance limit has slightly decreased with s Shear and bending mode in the link beam is dealt with in EBF frames, and if there is an architectural need and creating an opening in the frames, KBMF frame can be used with the failure of the link beam shear mode because it has Translated from Persian to English - www.onlinedoctranslator.com better stiffness and energy consumption. In this study, the behavior of steel and welding materials has been controlled by failure criteria in different parts of the connection and rupture mechanism
-
laboratory investigation of the effect of the stiffness of the bracing member on the behavior of the ecentrically braced frame
Reza Mehravi 2024يكي از سيستم هاي
-
بررسي مقايسه اي ويژگي هاي سطحي، خوردگي و زيست سازگاري آلياژهاي تيتانيوم پس از شستشوي اسيدي و اصلاح سطحي
QUSAY DAFTAR JWAID ALGUNASI 2024Dental implants are subject to complex mechanical and biological conditions. On the one hand, it is under cyclic pressure and corrosive environment, and on the other hand, chemical reactions occur on the surface of the implant with the biological environment. Therefore, not only surface conditions and topography, but also strength, fatigue resistance and biocompatibility will be important in the implant placement process. Currently, some grades of titanium such as grade 2, 4 and 5, as well as some alloys such as Ti-6Al-4V alloy and Ti-Ni duplex alloy are used by different manufacturers to make dental implants. Considerable information on the properties of these materials can be found in scientific sources, however, it is difficult to compare these materials in order to select appropriate materials for biological applications. Because the different working conditions for using these materials, as well as the history of the operations performed on these materials, make it difficult to compare them. In this research, the surface properties, corrosion, and biocompatibility of some titanium alloys will be studied after acid washing and surface modification under the same conditions. Keywords: implant - fatigue - titanium zirconium alloy.
-
Numerical study of the effect of slit shape with new geometry in slit dampers on the seismic performance of beam-to-column connections
Fatemeh Tanha sartakhti 2024connections experienced brittle failure. Therefore, in order to prevent the brittlefailure of connections and to protect the main structural members from damagedue to seismic forces, slotted steel dampers were used at the beam-to-columnjunction. The analyzes carried out in the finite element software showed that in thecase of using slotted dampers with a conventional slot shape, the stressconcentration is only created at the end points of the strips and the middle parts donot play a role in energy consumption. In order to solve this problem, in this study,semi-elliptical gaps were used in the slotted damper. Then, the influence of thewidth of the damper strips on the seismic performance of beam-to-columnconnections was investigated. The results of the analysis showed that the use ofthe proposed slotted damper improves the seismic performance of the connection.Also, by reducing the distance between the slits, the participation rate of the middleparts of the slitted damper strips in energy absorption increases. In the next step,the effect of the distribution of the height of the slits on the behavior of the slotteddamper in beam-to-column connections was investigated. The results ofexamination of the samples in the finite element software showed that thedistribution of the height of the slits in the slotted damper with the shape of a halfelliptical slit with a slope of 2 degrees in such a way that the lowest slit height isin the corner and the highest slit height is in the middle, has the highest energyabsorption and ultimate resistance.Key words: earthquake, slit damper, semi-elliptical slot, strip width, slit heightdistribution
-
experimental study of a method to improve the seismic performance of EBFs with flexural beam
Omid Moradbaigi 2023 -
Synthesis and characterization of chitosan/magnesium oxide/carbon quantum dots nanocomposite coating on 316 stainless steel alloy by sol-gel method for antibacterial applications
Mahsa Basati 2023 -
Estimation of ?^'Nanoparticle Volumetric and sizes in Inconel 738 Superalloy Using Neural Network
Shamila Hajjari 2023هدف،
-
investigation of recycled zirconia blocks by combining two methods of gel casting and cold isostatic press
Maedeh Takesh 2023 -
The effect of surface modification on super hydrophilicity behavior of titanium.
Sara Karami 2023In this research, the effects of sandblasting variables, including mesh size, pressure, distance and time of particle spraying, on the hydrophilicity and roughness of titanium samples were investigated. For this purpose, the desired surface properties were obtained by cleaning the samples through two-step acid washing. After each step, the samples were tested in terms of roughness and hydrophilicity. Also, the surface morphology of the samples was analyzed by scanning electron microscopy (FESEM) in order to determine the best acid washing time. Various biological tests including cell culture, cell toxicity, antibacterial, and protein adsorption were also performed on the samples. SEM images obtained from the sandblasted samples showed that increasing the acid washing time from 5 min to 10 min in the second acid solution results in a rough titanium surface with smaller surface pores. In order to enhance the hydrophilicity of the surface and thus, to reduce the stabilization time of the implants in the dental cavity, the samples were exposed to various surface treatments such as nitrogen plasma, liquid nitrogen washing, visible light irradiation, and hydrothermal treatment. Then the samples were stored in 5X solution in nitrogen atmosphere for 5 months. After that, hydrophilicity, protein absorption, cell culture, MTT, and antibacterial tests were performed on the samples. XRD analysis performed after hydrothermal treatment also showed that the structure of titanium has changed to anatase phase. Hydrophilicity tests showed that the wetting angle of all the samples is less than 10?. Therefore, it can be concluded that superhydrophilic properties have been achieved in all the titanium samples. Nitrogen plasma and hydrothermal treatment showed the most effect on the superhydrophilic properties. In addition, the highest protein adsorption (0.110) and cell adhesion was achieved after hydrothermal treatment. The results of antibacterial test also showed that surface activation methods have no significant effect on antibacterial properties.
-
Investigation on the effect of multilayer cladding of carbon steel by Inconel 625 ondeteriorative properties
Alireza Masoudi 2023 -
Bioactivity characterization of alkali anodized titanium
Hanieh Rostampour 2023Due to their favorable biocompatible properties, titanium and its alloys are used as popular raw materials for making all kinds of implants. Therefore, the efficiency of the implant is always being developed in order to better adapt to the biological tissue and increase its retention time in the place of cultivation, in different ways that lead to the creation of an oxide layer on the surface. The aim of this research is to investigate the biocompatibility of titanium in different morphologies obtained from anodizing in alkaline and acidic electrolytes.
-
Investigation of the effect of some variables of sandblasting process, acid washing and heat treatment on the surface properties and cellular response of titanium.
Dariush Danyali 2022In recent years and with the increase in the number of elderly people in different countries, the supply and demand for the use of titanium and its alloys in the manufacture of implants used in the human body such as hip joint prosthesis, joint replacement, knee replacement, fracture fixation and dental implants have increased. has increased widely. In medical applications, in addition to the usual properties of alloys, other factors such as topography and surface energy are also considered, which play an important role in the adhesion of bone cells to the implanted surface. As a result, the surface of the material plays an important role in the body's response to the implantable material. The purpose of this research is to investigate the effect of some variables of the sandblasting process, acid washing and heat treatment on the surface characteristics and cellular response of titanium. In order to modify the surface of the titanium substrate, first the samples were sandblasted using alumina powder, then they were etched in a solution containing nitric acid and sulfuric acid for the necessary time. After that, the samples were placed in the oven at temperatures of 300, 400, and 500 degrees Celsius for one hour. A group of samples were left without heat treatment. In order to measure roughness, hydrophilicity, investigate surface morphology, investigate phase compounds, cytotoxicity and biocompatibility of substrates, various tests and equipment including roughness meter, water contact angle measurement system, XRD, cytotoxicity and SEM were used to investigate cellular morphology. The results of the X-ray diffraction test showed that the dominant phase formed is the Ti6O phase. Of course, a small amount of Ti2O3 was also formed. The above groups cause better calcium deposition through reaction with body fluids. And the results of the hydrophilicity test showed that the amount of wetting angle ?m decreased with increasing sandblast pressure and especially with heat treatment compared to the control samples. However, in most of the samples, by increasing the temperature of heat treatment to 500 degrees Celsius, the contact angle has increased and the wettability has decreased. Regarding the evaluation of cell viability, the produced levels did not show any signs of cytotoxicity. In fact, the roughness of the surfaces obtained after sandblasting and acid etching were able to strengthen the attachment and proliferation of MG-63 cells on their surfaces.
-
Titanium surface modification to enhance hydrophilicity and bioactivity properties by alkali treatment
Poneh Moradzadeh 2022 -
The Effect of geometric variables on fatigue and mechanical stability on dental implants Using finite element method (FEM)
Mohammad Reza Pasandeh 2022Implant Insertion is not always successful, Because of inappropriate stability of implant-bone intersection. It seems implant geometrical including length, diameter, Number and depths flutes are affected on stresses and mechanical stability. The purpose of this research is study of implant geometrical variable such as numbers, angle and length of vertical grooves (Flute) on stress distribution and the amount of the implant displacement during static and periodic loads using finite elements Method (FEM) according to ISO 14801 international Standard. founded, that the effect of geometrical variables such as the length of the groove on the implant stem, the angles and Flute’s Number on the overall life of the dental implant and the amount of displacement after implantation has been very effective, so that the diagonalization of the groove has increased the tension better and its length is also more optimal in the original implant. Convergence of geometric variables such as alpha 6 degrees, beta 12 degrees, three grooves, with a fixed groove length will increase the life and stability of the implant by reducing the displacement of the implant in the anchor(bone). Since creating the final torque on the abutment causes the mechanical stability of the dental implant, the torque and loading couple will also stabilize the implant in the bone and increase its lifelog. When the abutment in the implant is tightened with a torque of 35 newton.mm. It causes more stability through more engagement with the surrounding bone.
-
Experimental study and simulation of resistance spot welding parameters And corrosion behavior on High-strength low-alloy steel (HSLA)
Arman Baigvand 2022 -
Fabrication of Ni-W-SiC-TiO2 nano-composite coating using electro-deposition methode.
Seyed hadi Taheri ghahfarokhi 2022Review : There are various methods of surface coating to deal with corrosion and wear and other surface damage. One of the easiest and most economical coating methods is electroplating or electroplating. In the past, the best element for electroplating coating was chromium, but today, due to the toxicity of the ions obtained from the chrome plating bath, nickel is used instead of this element. Nickel coating is alloyed with elements such as tungsten, molybdenum, cobalt, etc. for better properties. One of the innovations that has led to the production of coatings with better properties and performance is composite coating through the deposition of base and reinforcing nanoparticles. TiO2 and SiC hard nanoparticles are among the most widely used nanoparticles for creating composite coatings. The simultaneous presence of these Nanoparticles in the coating, if they are properly dispersed, can give the coating good chemical and physical properties. In this research, nickel-tungsten coating along with TiO2 and SiC nanoparticles were applied with direct plating current on the substrate of low carbon steel and their wear and corrosion behavior was investigated. The effect of variable Ph parameters, plating time, plating current density, the amount of nanoparticles in the plating bath, and the presence of ultrasonic waves during plating were investigated. In order to check the wear resistance of the pin on the disk, the corrosion resistance of the polarization test was used to determine the existing phases as well as the grain size by X-ray diffraction patterns (XRD) and to check the microstructure of the coating by field emission scanning electron microscope (FESEM). The results showed that for nickel-tungsten coating, the optimal pH is 7.5 ± 0.5 and the optimal current is 200 mA/cm2. Adding TiO2 nanoparticles to the plating bath increased the wear and corrosion resistance as well as the hardness of the coating and reduced the size of the crystals. Adding SiC nanoparticles to the bath led to an increase in hardness and wear resistance, as well as a decrease in crystal size and corrosion resistance. Coating in the presence of ultrasonic waves with powers of 40 and 60 led to an increase in the abrasion properties and hardness of the coating, but the increase in the power of the ultrasonic waves led to a decrease in these properties, which is due to the distortion and removal of particles from the surface of the coating due to the high power of the ultrasonic waves. is. In all the powers of the ultrasonic waves, the corrosion resistance decreased due to the cracks in the microstructure.
-
Optimization of arsenic removal using magnetite modified chitosan Nano composite in aqueous solution by response surface methodology
Safar Ahmadvand 2022Abstract Today, pollution of aquatic ecosystems with a wide range of organic and inorganic pollutants has become one of the biggest human challenges, so that research studies examining techniques and the use of effective attractants in reducing and Or the elimination of some of these harmful pollutants, including arsenic, has many study priorities. The aim of this study was to optimize the adsorption conditions of arsenic heavy metal from water using magnetite-chitosan composite nanosorbent. The advantage of using chitosan coating is higher adsorption capacity and higher stability of adsorbent nanoparticles and its easy separation from aqueous solution. In this study, first magnetite nanoparticles were synthesized by co-precipitation method of iron (II) and (III) chloride ions and the obtained nanoparticles were first identified by FT-IR spectrum, then UV-Visible spectrum, TEM, XRD, VSM. , DLS, Zeta potential were obtained. After reviewing the results and obtaining the result, carboxymethylcytosans were sonochemically bonded to the surface of the modified magnetite nanoparticles and the surface of the magnetite nanoparticles was coated with carboxymethylcytosane. Magnetite-chitosan composite nanoparticles were taken by material analyzers, first FT-IR, UV-Visible, XRD which showed the presence of magnetite with chitosan coating, then TEM, VSM images, magnetic saturation change of nanoparticles after coating Delivery, DLS particle size distribution and Zeta potential surface load were investigated. Then, the adsorption test was performed using Design Expert software and the experiment was designed with Taguchi model from four factors: adsorbent dose, pH, temperature and time, and arsenic solution with an initial concentration of 1 ppm. Residual arsenic concentration was measured by ICP-Mass and statistical operations were performed on the test results and the effect of various factors on the adsorption efficiency was shown as contours so that the adsorption efficiency increased with increasing adsorbent dose and with increasing pH of The adsorption efficiency increased from 3.5 to 8.5 at a certain dose and the increase in temperature and time also increased the adsorption. Dose was 0.0300 g and pH = 3.5, contact time was 1440 min and temperature was 35 ° C. The optimal absorption point with 99.3% yield was obtained at a dose of 0.0283 g and pH = 6.4, and the contact time was 976 min and the temperature was C38, and the validation test showed a value of 99.4%. The weight ratio of chitosan to magnetite was synthesized in four different ratios of 1: 1, 2: 1, 3: 1 and 4: 1, and in optimal adsorption conditions, a test was performed. . Using the linear, nonlinear Langmuir equations and then the linear and nonlinear Friendlich isotherms, the isotherm that was consistent with the adsorption process and showed the highest correlation coefficient was the linear Langmuir and Friendlich isotherms, which obtained the maximum absorption capacity from the equation. The magnetite-chitosan composite was calculated to show 313.57 mg / g. According to the obtained results, the synthesized nanocomposite can be used for water filtration and arsenic adsorption under optimal conditions.
-
effect of silicone/graphene nano composite coating on the corrosion behavior of the steel substrate
Amir Edrisii 2021 -
characterization of ti-Hydroapatite/bioglass nanocomposite fabricated by friction stir processing
Gholamhossein Amiri 2019 -
Effect of nanometric surface roughness and bioactive glass coating on bioactivity properties of titanium
Mahdi Mohammadnezami 2019 -
calcium phosphate on the titanium substrate using biomimetic Method : Effect of surfface topography in nano micro and macro scale on the coating morphology
Fatemeh Khodaee 2019 -
مطالعه اثرات گوشه بر روي تغييرشكل و سطوح گسيختگي ديوار ميخكوبي شده تحت بارهاي سرويس
Ali Ghahramani 2019اين تحقيق به منظور نشان دادن تاثير زواياي گوشه و هندسه گودبرداري بر روي تغييرشكل ها و سطوح گسيختگي اطراف گود ميخ گذاري شده، انجام شدهاست. در اكثر تحقيقات صورت گرفته به بررسي و تحليل عناصر پايدارسازي ديوارهي گود با فرض كرنش مسطح و بهصورت مسئله دوبعدي پرداخته شده است، حال آنكه مسئلهي پايداري در گوشههاي گود و اثرات هندسه و شكل گود از جمله موضوعات مهم و تاثيرگذار بر پايداري و كنترل تغييرشكلها و سطوح گسيختگي مي باشد. در اين تحقيق از نرمافزار اجزاءمحدود Abaqus CAE-2016 استفاده شده و مدلرفتاري مورد استفاده در اين تحقيق موهر-كولمب در نظر گرفته شده است. عمده تمركز اين تحقيق بر تغييرشكل سه بعدي گود و نشان دادن اثر گوشهي گود است به همين منظور بررسي تغييرشكلهاي افقي و قائم گود و سطوح گسيختگي آن انجام ميگردد. در اين تحقيق براي بررسي اثر هندسه و گوشه گود، 4 حالت مختلف براي گوشه گود در نظر گرفته شده است؛ حالت گود مقعر با زاويه ي گوشه 60درجه، 90درجه، 120 درجه و حالت گود محدب با زاويه ي گوشه 270 درجه؛ كه براي هر كدام از حالتهاي ذكر شده از سه مدول الاستيسيته مختلف براي ميخها بررسي گرديده كه بتوان تاثير همزمان بازدارندگي گوشه گود را با تغيير مدول الاستيسيته ميخها بررسي كرد. با استفاده از تحليلهاي عددي اثر مدول الاستيسيته و اثر زاويه گوشه گود برروي تغييرمكانها و نشستهاي ايجاد شده با فاصله گرفتن از سطح ديوارهي ميخگذاري شده و تغييرشكل ديواره گود در گوشههاي گود با ديوار ميخگذاري شده و محل سطوح گسيختگي بحراني در حالت سرويس مورد ارزيابي قرار ميگيرد. در اين تحقيق بار سرويس متشكل از بار يكنواخت 135kpa بر روي سطح كل گودبرداري است. كه نتايج كلي مشهود از اين تحقيق، تاثير بازدارندگي گوشههاي گود مقعر مي باشد، بهطوري كه هرچه گوشه گود داراي زاويهي كمتري باشد اين تاثير بازدارندگي در نشستهاي سطحي و تغييرمكان افقي ديوارهي گود بيشتر است اما با كم شدن بيشتر زاويه گوشه اين تغييرات كمتر شده و بهينه نيست، بهترين زاويه كه تاثير بازدارندگي بهينه را دارد زاويه 90 درجه ميباشد. براي حالت محدب عكس اين موضوع اتفاق ميافتد و اثر تحدب در گوشه باعث ناپايداري در گود افزايش در مقدار نشستها خواهدشد. تاثير سختي ميخها نيز مشابه تاثير گوشه گود است به طوري كه با افزايش سختي، كاهش در مقدار نشستهاي سطحي و تغييرمكان افقي ديواره ي گودبرداري مشهود ميگردد. در حالت محدب كه گود به حالت ناپايداري نزديك ميشود مي توان با ميخهايي با سختي زياد اين اثر افزايش نشست را تا حدود زيادي كاهش داد. كرنش هاي برشي پلاستيك باعث ايجاد 2ناحيه در گودبرداري ميگردد، با نزديك شدن به گوشه گود، ناحيه 2 كه ناحيه اي فعال و محرك است به تدريج از ناحيه 1 كوچكتر شده و گود پايدارتر ميگردد، اين اثر زاويه گوشه بر روي گوه هاي گسيختگي به اين شكل است كه با كوچكتر شدن زاويه گوشه تا 90درجه اين تاثير چشم گير است اما با كاهش بيشتر آن تغيير زيادي نسبت به مدل 90درجه مشاهده نمي گردد. براي حالت محدب نيز گوه هاي گسيختگي بسيار به لبه گود نزديك شده و حالت بحراني رخ مي دهد.
-
Extraction fetal ECG from abdominal Recordings Based on Sparse Represntation
Parya Tavoosi 2018Neonates and infants are the most likely group to present with congestive cardiac failule, one of the most cause of mortality in newborns, so that, one out of 125 are born ech year with some form of heart failure. This cardiac failure ranges from mild to severe in terms of severity.In has been well established that the early diagnosis of cardiac disease in the embryyonic period may prevent the cardiac failures after birth and consequently decrease the rate of mortality in newborns.Recording heart electrical activity by electrocardiogram is commonly used to detect abnormal arrythmias. How ever the non-invasive extraction of fetal ECG from maternal abdominal is challenging, since the fECG signals are aften corrupted by electrical noise from other sources such as maternal heart activity, uterine contractions and respiration, in addition to instrumental noise.Many approaches has been presented to non-invasively extract fECG, However their performance are not entirely satisfactory. Among all exising methods Blind Sourse Seperation have been of great interest to researchers for many applications. In this thesis, we use the method of time-frequency based blind source separation method for the separation of Convolutive Mixtures. We also use the Compressive sensing and the fast independent component analysis method to reduce the complexity of the signal.We apply our proposed method to the database in the 2013 Physionet Challenge and compare the results with existing methods using Compressive Sensing and Independent Component Analysis, which yielded a Mean squar Error of 171.65 and a time of 7.85 minutesKeywords: Fetel Electrocardiogram signal, Blind Source Seperation, Time-frequency analysis, Convolutive Mixtures, fast independent component analysis, Compressive sensing, Discet Wavelet Transform
-
Research on Mechanical Properties of welds in SAW in the Presence of SiO2 Nano-Particles using Taguchi Method
Sajad Mohamad khani 2018 -
اصلاح سطح تيتانيوم به وسيله پوشش كلسيم فسفات غني شده توسط روي و منيزيم
Parvaneh Sahmohamadi 2018 -
Simulation of crack growth during rolling contact fatigue wear of austemperd ductile iron
Arezu Faraji 2018شبيه سازي رشد ترك در چدن نشكن آستمپر شده تحت سايش خستگي
-
TLP bonding simulation using artificial neural network
Behjat Almasi 2018 -
Dynamic behavior of steel moment frames with asymmetric plan with seismic isolation
Hanyeh Khasian sarabi 2018دو عامل اصلي در صدمه ديدن سازه ها و محتويات آن ها در حين زلزله، تغييرمكان هاي نسبي و شتاب هاي ايجاد شده در سازه هستند. طرح هاي لرزه اي همواره به دنبال كاهش اين دو عامل و درنتيجه كاستن خسارات وارده مي باشند. جداسازي پايه در سازه ها به طور همزمان موجب كاهش قابل توجهي در مقادير تغييرمكان هاي نسبي و شتاب هاي ايجاد شده در سازه مي شود و لذا با كاربرد سيستم جداسازي لرزه اي علاوه بر امكان طراحي يك سازه مطمئن مي توان به عملكرد اجزاي غيرسازه اي و محتويات سازه نيز در موقع زلزله مطمئن بود. تحقيقات نشان داده اند كه استفاده از ميراگرهاي ويسكوز مي تواند نقش موثري در كنترل پاسخ سازه ها در برابر باد، انفجار و زلزله داشته باشد] 2و1 [. اكثر سازه ها هنگام زلزله هاي شديد با كمك شكل پذيري اعضا با آن مقابله مي نمايند كه سبب آسيب هاي اساسي و بعضا غيرقابل جبراني به اعضاي سازه اي و غيرسازه اي مي گردد. استفاده از ميراگرها مي تواند تغييرمكان ها و شتاب هاي زياد سازه و به تبع آن نياز به شكل پذيري را كاهش دهد. در حال حاضر كشورهاي پيشرفته با مناطق زلزله خيز مانند ايالات متحده، ژاپن و نيوزيلند پيشگامان استفاده از جداسازي لرزه اي در جهان هستند و جداسازي پايه در سازه ها به عنوان رويكرد جديد مقاوم سازي لرزه اي مطرح شده و جنبه عملي به خود گرفته است. در كنار اين رويكرد بسترهاي تحقيقاتي فراواني به وجود آمده است كه تمام مراحل توليد تا اجراي سيستم هاي جداساز را شامل مي شود و تحليل ديناميكي سازه هاي جداسازي شده يكي از مهم ترين اين بسسترها است.مي دانيم كه پيچش اثر معكوس بر پاسخ سازه هاي مرسوم همچنين سازه هاي جداسازي شده مي گذارد. به دليل آنكه 42% تخريب ها در طول زلزله 1985 در شهر مكزيك بخاطر پاسخ پيچشي ساختمان هاي نامتقارن بود، آيين نامه فدرال مكزيك(2و1) اين فلسفه طراحي را براي سازه هاي مرسوم، از سال 1987 معرفي كرده اند و ديگر آيين نامه هاي مكزيكي مثل منيول سازه هاي مهندسي در اين فلسفه سهيم اند. طبق اين فلسفه اگر خروج ازمركزيت هاي پلان محاسبه شده براي هر طبقه از 10% بعد پلان در جهت داده شده بيشتر باشد به عنوان سازه هاي نامتقارن طراحي شود و اگر خروج ازمركزيت از 20% بيشتر شود آن ها بايد به عنوان سازه هاي شديدا نامتقارن طراحي شود.هدف اين پايان نامه بررسي اثر جداسازي پايه بر سازه هاي نامتقارن جرمي است. به اين منظور سه مقدار خروج از مركزيت جرمي 10% ، 20% و 30% در سازه با پاي ثابت و سازه جداسازي شده در نظر گرفته شد و پاسخ تغييرمكان هايشان با هم مقايسه شد. جداسازي اثر پيچش را در سازه به ميزان قابل توجهي كاهش مي دهد. جانمايي جداساز و ميراگرها به گونه اي تنظيم شد تا در هر خروج از مركزيت جرمي، مركز سختي و ميرايي سيستم جداسازي در گام هاي 5% درصدي روي محوري كه از مراكز جرم مي گذرد تغيير كند. سپس پاسخ تغييرمكان روسازه و زير سازه در تمام اين حالت ها تحت 7 شتاب نگاشت منتخب مطالعه و با هم مقايسه شدند. در واقع هدف از مطالعه جانمايي جداسازها و ميراگرها، بهينه كردن تغييرمكان هاي روسازه و زيرسازه به صورت همزمان است، به گونه اي كه جداسازي به بهترين نحو پاسخ هاي سازه نامتقارن جرمي را به سازه متقارن نزديك كند.واژه هاي كليدي: سازه هاي نامتقارن جرمي، جداساز لاستيكي با هسته سربي، ميراگر ويسكوز غيرخطي، تحليل ديناميكي غيرخطي، سازه جداسازي شده
-
Fabrication and characterization of magnesium - based tissue engineering scaffold by replication method
Amirhamed Aghajanian 2018 -
Investigation of effect of the plastic deformation on mechanical and wear properties of AL7075.AL2O3
2017 -
0
KEYNOOSH BATEBI 2016Nowday injuries of hard tissues, forcing us to replace and fix them. In this regard, metal implants and among them titanium and its alloys has the most applications. In order to improve the biocompatibility and bioactivity of them, calcium phosphate coatings, especially hydroxyapatite, on which they are applied. The presence of silver ions in the structure of hydroxyapatite signifcatnly reduces the implant site infections, because of its antibacterial properties. Fluorine ions that are normally present in bone structure, in addition to improving the biocompatibility also have antimicrobial effects. A composite coating containing silver, fluoride and hydroxyapatite (Ag-FHA) was developed on titanium substrate by sol-gel method. Triethyl phosphite, hydrated calcium nitrate, ammonium fluoride and silver nitrate were used respectively, as P, Ca, F and Ag precursors with a Ca:P ratio 1.67 and concentration of silver was 0.3 wt.%. Coatings were characterized by Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), field-emission scanning electron microscopy (FE-SEM) and Atomic absorption spectrometry (AAS). Results showed that in presence of such a low concentration of silver in hydroxyapatite can’t make significant changes in its structure. In presence of fluoride the crystallite size reduced from 29 to 11 nm and the films, with 1.3 micrometers thickness, showed a uniform and dense morphology. Corrosion behavior in SBF at 37 °C showed that the corrosion resistance of coatings increased with increasing the amount of fluoride. Antibacterial activity of coatings against Escherichia coli indicated a significant enhancement in the antibacterial property of Ag-FHA nanocomposite with increasing the amount of fluoride. These coatings can prevent the bacterial infections of implants
-
بهبود ساختار سطحي آلياژ ...(نيكل-آلومينيم برنز) با استفاده از نانو ذرات اكسيد آلومينا به روش اصطكاكي اغتشاشي
2015 -
Transient liquid (TLP) bonding of .... using electropleted interplayer
2015 -
Bituminous coal desulfurization and de.ashing orocesses by column flotation
2015 -
بررسي تغيير شكل گرم چدن نشكن ريخته گري شده به روش نيمه جامد
2014 -
bending fatigue behavior of stainless steel 420 AISI under very short heat treatment
Samaneh Rasouli 2014 -
The effect of homogenization process on the mechanical properties and microstructure of the TLP bonded FSX-414 / MBF80/IN738
Abbas Jahanbakhsh 2014 -
production o activeted carbon from waste biomass
2011

